Intrinsically Safe PCB Design: 9 Rules That Keep You Certifiable

Designing electronics for hazardous environments requires careful control of electrical and thermal energy. This blog covers 9 essential rules for intrinsically safe PCB design, including energy limitation, stored energy, creepage and clearance, circuit separation, component selection, thermal management, and certification considerations.

ISO 9001 Certified

Quality System

In-House Manufacturing

Lafayette, LA

100k+ Boards / Year

3 Production Lines

PCB Design

ATEX / Class 1

Div 1 Ready

Engineering trusted by operators & OEMs across the Gulf Coast & Permian

What are the design rules for intrinsically safe circuits? The key design rules for intrinsically safe circuits include limiting electrical energy, controlling voltage and current, managing stored energy, maintaining adequate creepage and clearance, separating circuits, and selecting suitable components. These measures help prevent sparks or thermal effects from igniting an explosive atmosphere and support the applicable certification requirements.

Intrinsically safe (IS) design is a specialized approach used for electronics that may operate in hazardous environments. Rather than relying only on an enclosure to contain an ignition source, an intrinsically safe circuit is designed so the available electrical and thermal energy remains below levels capable of causing ignition. For equipment intended for hazardous locations, hazardous location electronics design needs to account for these requirements from the earliest stages of PCB development.

What Is Intrinsically Safe PCB Design?

Intrinsically safe PCB design focuses on controlling the energy available within an electrical circuit. The design must consider both normal operation and specified fault conditions.

Depending on the application, this can involve controlling:

  • Voltage
  • Current
  • Power
  • Capacitance
  • Inductance
  • Temperature
  • Stored electrical energy

The objective is to ensure that the circuit remains within the required safety limits under the applicable conditions.

1. Control Voltage and Current

Voltage and current are fundamental considerations in an intrinsically safe circuit. The design should establish clear limits for the energy that can enter and remain within the hazardous-area circuit.

This may require careful selection of:

  • Power supplies
  • Resistors
  • Current-limiting components
  • Regulators
  • Protection components
  • Signal interfaces

Limiting energy at the circuit level helps reduce the possibility of an ignition-capable electrical event.

2. Manage Stored Energy

A circuit can store energy even when the immediate power input is limited. Capacitors and inductors are particularly important because they can store electrical or magnetic energy that may later be released.

Designers should therefore evaluate:

  • Capacitor values
  • Inductor values
  • Stored energy
  • Discharge paths
  • Component tolerances
  • Fault conditions

The analysis should consider the maximum credible energy that could become available during operation or a relevant fault.

3. Maintain Appropriate Creepage and Clearance

PCB layout plays an important role in maintaining electrical separation. Creepage refers to the shortest distance along the surface of an insulating material between conductive parts, while clearance refers to the shortest distance through air.

The required distances depend on factors such as:

  • Working voltage
  • Insulation requirements
  • Material properties
  • Pollution conditions
  • Applicable standards
  • Circuit classification

These distances should be established during PCB layout rather than being treated as a final inspection item.

4. Separate Intrinsically Safe and Non-IS Circuits

Where intrinsically safe and non-intrinsically safe circuits exist within the same equipment, appropriate separation becomes important. The PCB and system architecture should prevent energy from a non-IS circuit from being unintentionally transferred into the intrinsically safe circuit.

This may involve:

  • Physical separation
  • Isolation
  • Barriers
  • Controlled routing
  • Appropriate component placement
  • Defined interface points

The separation strategy should be considered across the complete electrical and mechanical design.

5. Use Appropriate Energy-Limiting Barriers

Barriers can help control the amount of energy entering an intrinsically safe circuit. Depending on the design, energy-limiting approaches may involve components such as resistors, Zener diodes, fuses, or other protective elements.

The selected approach should be evaluated under normal operation and applicable fault conditions. Component tolerances and failure modes also need to be considered because a design that works only under ideal component values may not provide sufficient safety margin.

6. Consider Component Failure Modes

Component selection should go beyond checking nominal electrical specifications. For intrinsically safe designs, engineers need to understand how components behave when they fail.

Consider whether a component could:

  • Short circuit
  • Open circuit
  • Overheat
  • Release stored energy
  • Change electrical characteristics
  • Transfer excessive energy to another part of the circuit

Understanding these failure modes helps engineers evaluate whether the circuit can remain within its required safety limits.

7. Control Thermal Effects

Ignition risk is not limited to electrical sparks. Surface temperature can also become important in hazardous environments.

Components that generate significant heat should therefore be evaluated for:

  • Normal operating temperature
  • Fault conditions
  • Power dissipation
  • Thermal coupling
  • Ambient temperature
  • Enclosure effects

Thermal analysis can help ensure that accessible surfaces and components remain within the applicable temperature requirements.

8. Design the PCB With Certification in Mind

Certification requirements should influence the PCB design from the beginning. Layout decisions involving component spacing, circuit separation, barriers, grounding, energy storage, and routing can all affect the certification process.

A design that is developed with these requirements in mind can make later technical review more straightforward. It is also important to maintain accurate schematics, PCB layouts, component information, calculations, and design records throughout development.

9. Validate the Design Through Testing and Documentation

A well-designed intrinsically safe PCB still needs appropriate verification. Depending on the product and applicable certification pathway, validation may involve:

  • Electrical testing
  • Temperature testing
  • Fault-condition evaluation
  • Component verification
  • Documentation review
  • Construction assessment

Testing should be supported by clear technical documentation showing how the design meets the applicable requirements.

Why Intrinsically Safe Design Requires Early Planning

Intrinsically safe requirements can influence fundamental product decisions. Changing the circuit architecture late in development may affect the PCB layout, components, enclosure, power system, and interfaces. For this reason, engineers should establish the safety requirements before the PCB design becomes difficult to change. Early planning can help the team identify energy-limiting strategies, separation requirements, and component constraints before they become expensive redesign issues.

Certification and Quality Considerations

A certifiable product needs more than a carefully designed circuit. The engineering process should also provide clear evidence that design decisions, components, testing, and verification have been properly documented. Reviewing our certifications and quality standards can provide additional context on how quality and verification processes support engineering projects. Maintaining organized technical records can also make it easier to demonstrate how the product was designed and evaluated.

Intrinsically Safe PCBs for Oil and Gas Equipment

Oil and gas applications can place demanding requirements on electronic equipment because products may operate in hazardous areas with challenging environmental conditions. The application should be considered alongside the electrical design, including the hazardous classification, operating environment, temperature, power requirements, and intended installation. Experience in oil and gas engineering can help connect these application requirements with the engineering decisions involved in developing hazardous-location electronics.

What Makes an Intrinsically Safe PCB Certifiable?

There is no single PCB feature that makes a design intrinsically safe. Instead, certification depends on how the complete design addresses the applicable requirements.

strong development approach considers:

  1. Energy limitation
  2. Stored energy
  3. Creepage and clearance
  4. Circuit separation
  5. Barriers
  6. Component behavior
  7. Thermal performance
  8. PCB construction
  9. Testing and documentation

These elements should work together as part of the overall product design.

Final Takeaway

Intrinsically safe PCB design requires careful control of electrical and thermal energy throughout the product. Creepage and clearance, energy storage, circuit separation, barriers, component selection, thermal performance, and fault-condition analysis all contribute to a design that can progress toward certification.

The earlier these considerations are incorporated into the PCB and system architecture, the easier it can be to develop a product around its intended hazardous-location requirements. If you are developing an intrinsically safe PCB for a hazardous environment, send your specs to an engineer to discuss your product requirements and design considerations.

Frequently Asked Questions

1. What are the design rules for intrinsically safe circuits?
Key rules include limiting voltage and current, controlling stored energy, maintaining appropriate creepage and clearance, separating circuits, managing thermal effects, and evaluating component fault conditions.
2. What makes a PCB intrinsically safe?
An intrinsically safe PCB is designed to keep electrical and thermal energy below ignition-capable levels under normal operation and applicable fault conditions.
3. Why is creepage important in intrinsically safe PCB design?
Creepage helps maintain the required electrical separation between conductive parts along the surface of the PCB and supports safe circuit operation.
4. Do intrinsically safe PCBs need special components?
Components may need to meet specific electrical, thermal, reliability, and fault-condition requirements based on the circuit and applicable certification standards.
5. Why are barriers used in intrinsically safe circuits?
Barriers can help limit the amount of electrical energy that can enter or reach an intrinsically safe circuit.

On This Page

Designing for a hazardous area?

Send your area classification and requirements. The engineer who’d design your hardware reviews it — no sales handoff.

ISO 9001 · IPC-A-610

Certified Quality

ipc
Engagement

From Requirements to Field Support

Cross-Disciplinary Expertise

Industries We Serve

Rooted in oil & gas automation, Pelican brings robust electronic design and manufacturing to highly regulated, demanding sectors.

Energy & Oil/Gas

Harsh-environment controllers, downhole sensor integration, and HazLoc-compliant electronics for the Permian and beyond.

Defense

Ruggedized embedded systems, secure telemetry, and reliable PCB assemblies built for shock, vibration, and extreme temperatures.

Medical Devices

Precision instrumentation electronics, low-noise analog signal processing, and strict lifecycle traceability.

Food Safety

Automated monitoring and control systems tailored for compliance, hygienic environments, and precise thermal management.

Industrial Controls

Factory automation PLCs, custom motor drives, and IoT edge devices supporting legacy and modern protocols.

Discuss Your Industry

Specific regulatory or environmental requirements? Let our engineers review your spec sheet.

Free Resource

The Hazardous-Location Design Checklist

A one-page engineering checklist covering area classification, protection method selection, enclosure and temperature codes, and the certification path — the questions to answer before you commit to a hazardous-location hardware design.

Standards & Trust

Quality Certifications & Compliance

We operate to the highest industrial standards — confidence in manufacturing reliability, engineering precision, and regulatory adherence.

ISO 9001

Certification underscoring our dedication to rigorous quality standards — consistently delivering products of the highest quality, from customer interactions to product development.

IPC-A-610

Our manufacturing staff holds IPC-A-610 certification — governing the acceptability of electronic assemblies and ensuring our processes meet or exceed benchmarks for reliability and safety.

LAPELS

Three licensed Professional Engineers accredited by the Louisiana Professional Engineering and Land Surveying Board — advanced expertise and adherence to professional and ethical standards.

Engineered for Global Regulatory Compliance

HazLoc / ATEX

Intrinsically safe & explosion-proof designs
(Class I, Div 1/2).

UL / cUL / CSA

Engineered to pass strict North American electrical safety standards.

RoHS & REACH

Compliant component sourcing and lead-free manufacturing for export.

FCC / CE

EMI/EMC-tested telemetry and wireless comms — no field interference.

Common Questions

Frequently Asked

What does Class 1 Division 1 mean?

It is an NEC hazardous-location rating for an area where ignitable concentrations of flammable gases or vapors are present continuously or intermittently under normal operating conditions. Equipment installed there must be certified so it cannot ignite that atmosphere.

Division 1 means the hazardous atmosphere is expected during normal operation. Division 2 means it is only present under abnormal or fault conditions, such as a container rupture or a failed ventilation system.

Class 1 Division 1 corresponds to IEC Zone 0 plus Zone 1. The Zone system splits the “normally present” case into Zone 0 (continuous) and Zone 1 (present in normal operation), so one Division 1 area covers both zones.

Group A (acetylene), Group B (hydrogen), Group C (ethylene), and Group D (propane, methane, natural gas, gasoline). Group D is the most common in oil & gas. The group determines which enclosures and protection methods are permitted.

It is tested and certified by a Nationally Recognized Testing Laboratory (such as UL or CSA) against the applicable standards, then marked with its Class, Division, Group, and temperature code. Designing for certification from the start is far cheaper than retrofitting.

Direct Line

Contact an Engineer

Send your area classification and project requirements. An engineer — not a salesperson — will follow up.