Medical Device Electronics Design & Manufacturing

Pelican Engineering is a medical device electronics design firm that takes Class I and Class II device hardware from requirements through production — designed, built, and tested under one roof in Lafayette, LA.
In-house floor
Typical design considerations — set per device
Signal path
Low-noise analog
Precision front ends for measurement
Isolation
Patient-side barriers
Creepage, clearance, leakage budgeting
EMC
Emissions & immunity
Stackup, filtering, cable entry
Traceability
Lot & revision control
Build records tied to each unit
Volume
1 → low-to-medium
Verification builds through production
Values shown are typical design targets. Actual requirements are set by your program specification.
Send it to an engineer
A licensed engineer reviews it — usually same day.




    1:1

    Direct engineer access

    One roof

    Design, firmware & build

    1 → 1,000s

    Prototype to production

    100%

    Fixture-tested pre-ship

    Built for Measurement You Can Trust

    Medical electronics fail in ways that matter differently. A noisy front end doesn’t crash — it produces a number someone acts on. We started there.
    “On a diagnostic instrument, failure mode isn’t a dead board. It’s a reading that looks plausible and isn’t. That’s a design decision, not a test finding.”

    Precision Signal Path

    Low-noise analog design, grounding, and shielding decisions made in the first layout pass — not corrected after a calibration problem appears.

    Isolation & Patient Safety

    Isolation barriers, creepage and clearance, and leakage current treated as layout constraints from the start.

    Firmware & Verification

    Control logic and measurement firmware written against the real board, with records that support your verification activities.

    Traceable Manufacturing

    Lot and revision control on assemblies built in the same facility that designed them.

    Have a defense program that needs a hardware partner?

    Class I and II Medical Device Electronics Design

    Device programs specify requirements against recognized standards. We as medical device electronics manufacturing partners, design them from the start, not after a failed pre-compliance scan.
    Standard
    IEC 60601-1
    IEC 60601-1-2
    ISO 14971
    IEC 62304
    Governs
    Electrical safety and essential performance
    Electromagnetic compatibility
    Risk management
    Software lifecycle
    How it shapes the design
    Isolation barriers, creepage and clearance, leakage current budgeting, protective earthing
    Stackup and return-path planning, filtering and shielding, connector and cable entry treatment
    Hazard analysis feeding component selection, derating, and defined failure behavior
    Firmware structure, documentation, and verification records appropriate to software safety class

    Electronics Design for Diagnostic Equipment

    We start with what the instrument must measure and work backward to the board.

    Measurement Accuracy

    Front-end design, reference selection, and grounding built around the resolution and stability the instrument needs

    Thermal & Drift

    Component and layout choices that hold calibration across the operating range, not just at bench temperature.

    Interfaces & Data

    Display, connectivity, and data handling matched how the instrument is used and how results leave it.

    Three layers, one team

    Most vendors own one layer and hand off the rest. On a regulated device, the gaps between them are where documentation and schedule both break down.

    Enclosure & interface

    Housing, sealing, and user-facing surfaces suited to cleaning and handling service.

    PCB & hardware

    Isolation, signal integrity, and EMC behavior are designed into the layout.

    Firmware & measurement logic

    Control and measurement code written against the real board, not a reference design.

    EMC Pre-Compliance
    RADIATED EMISSIONS
    CISPR 32 CLASS A LIMIT +6 dB — FAIL 30 MHz 1 GHz

    CHAMBER: 3 m SEMI-ANECHOIC

    POL: HORIZONTAL · 0–360°

    MARGIN: 4.2 dB

    RESULT: WITHIN LIMIT

    3rd HARMONIC → OVER LIMIT

    CISPRCE / FCCPre-compliance
    Hover to exceed the limit

    Medical Device Firmware Development

    Firmware written against the real hardware, with structure and records that fit a regulated development process.

    Measurement and control logic tied to the actual analog front end

    Fault detection, defined safe states, and diagnostic reporting

    Documentation and verification records scaled to software safety class

    Update paths for devices already in service

    Medical Device PCB Assembly Services

    Assemblies built to IPC-A-610 workmanship criteria on the same lines, in the same building, by the team that designed the board.

    Lot and revision control tied to each build

    IPC-A-610 certified assembly staff

    Dedicated test fixture verification before shipment

    Verification-quantity builds through low-to-medium-volume production

    A Medical Device Electronics Manufacturing Partner

    The wider disciplines a device program needs, alongside the digital and firmware work.

    Precision Analog

    Low-noise signal conditioning and instrumentation front ends.

    Sensor Integration

    Interfacing the transducers your device already uses.

    Power & Isolation

    Medical-appropriate supply and isolation architecture.

    Electromechanical

    Mechanical, electrical, and firmware in one team.

    Medical Device Applications

    Diagnostic, monitoring, and laboratory hardware.

    Diagnostic Equipment Electronics

    Measurement and control electronics for diagnostic instruments where accuracy and repeatability drive the design.

    Patient Monitoring & Instrumentation

    Precision front ends, isolation, and display electronics for monitoring and measurement devices.

    Laboratory & Benchtop Analyzers

    Control, sensing, and motion electronics for benchtop analytical and sample-handling equipment.

    Legacy Device Refresh

    Electronics redesign for devices in service facing component end-of-life, preserving footprint and behavior.

    Is your device program a fit?

    Four questions. You get the scope it implies, the risks worth flagging early, and a summary you can hand to an engineer.

    Why Device Manufacturers Choose Pelican

    A manufacturing partner, not a design-only shop.

    Direct Engineer Access

    Reach the engineer on your hardware, not a coordinator.

    Design & Build, One Roof

    The team that designs it also builds it in Lafayette, LA.

    Traceable Build Records

    Lot and revision control on assemblies, under an ISO 9001 quality system.

    Fixture-Tested Pre-Ship

    Every board checked on a dedicated fixture before it ships.

    Our Process

    1

    Requirements

    Device specification, classification, measurement targets, and volume.

    2

    Design

    Hardware, firmware, and enclosure together — isolation and EMC considerations built in from revision one.

    3

    Prototype & Verification Support

    Built and tested in-house against a purpose-built fixture, with records for your verification activities.

    4

    Manufacturing

    Low-to-medium-volume runs in Lafayette, LA, sized to your program.

    5

    Lifecycle Support

    Same team handles revisions, component obsolescence, and field issues.

    Standards & trust

    Quality Certifications & Compliance

    ISO

    ISO 9001

    Certified quality management across design and build.

    IPC-A-610

    Assemblies built and inspected to the industry standard.

    LAPELS

    LAPELS

    Licensed professional engineering practice.

    Frequently Asked Questions

    Does Pelican design Class I and II medical device electronics?
    Yes. Class I and II medical device electronics design is established here — our engineers have designed device electronics alongside hazardous-location and industrial hardware, and the same isolation, signal-integrity, and documentation discipline applies.
    Both. Pelican keeps electrical design, firmware, and low-to-medium-volume PCB assembly in-house, so the same team that designs the device’s electronics also builds and tests them. That removes the handoff between a design file and a contract manufacturer.
    Yes. Medical device firmware development sits with the same engineers who design the board, so measurement logic is written against the real analog front end rather than a reference design. Documentation and verification records are scaled to the software safety class your program requires.
    In most cases, yes. Component end-of-life redesigns are typically scoped to preserve the existing footprint, connectors, and behavior while requalifying the board around currently available parts which keeps the change as narrow as possible for your own documentation and revalidation work.
    Yes. We as one of the best medical device electronics design firms support single-unit and small-batch builds as well as production runs, so an early-stage program does not need a separate vendor before scaling volume.

    Contact an Engineer

    Send us your zone or division classification, gas group, temperature class, and target markets. An engineer—not a salesperson—will follow up.

      See what Pelican can build for your device.

      From a handful of units for design verification to a full production run — same engineers, same building.